5-48 Chapter 5: RAID conguration
5.4.9 Enabling the WriteCache
You may enable the RAID controller’s WriteCache option to improve the data
transmission performance.
When you enable WriteCache, you may lose data when a power interruption
occurs while transmitting or exchanging data among the drives.
To enable WriteCache:
1. From the Management Menu, select Objects > Adapter, then press
<Enter> to display the adapter properties.
2. Select WriteCache, then press <Enter> to turn the option On (enabled).
3. When nished, press any key to continue.
LSILogicSoftwareRAIDCongurationUtilityVerA.51Aug13,2007
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
Management Menu
Congure
Initialize
Objects
Rebuild
CheckConsistency
DiskWriteCache-Off(WriteThrough)orOn(WriteBack)
Objects
Adapter
Virtual Drive
Physical Drive
Adapter 0
Rebuild Rate = 30
ChkConstRate=30
FGI Rate = 30
BGI Rate = 30
DiskWC=Off
Read Ahead = On
Bios State = Enable
Stop On Error = No
Fast Init = Enable
Auto Rebuild = On
Auto Resume = Enable
DiskCoercion=1GB
Factory Default