17 • Schlage • Schlage Utility Soware User's Guide
Connecting the Handheld DeviceConnecting the HHD
Legacy PIM (BM-150 Only)
1 Start the Schlage Utility Soware.
2 Make sure the HHD is in Serial Connection Mode. See Connection Type on page 13 for more
information.
3 Connect the serial cable (HH-Serial) to the HHD and the null modem adapter (PIMWA-CV).
4 Connect the null modem adapter to the legacy PIM serial port.
5 Simultaneously press the RESET and the LINK A buttons on the Legacy PIM, then release the
RESET button while holding the LINK A button.
6 Continue holding the LINK A button (at least 15 seconds) until communication is established
and the device name is displayed on the SUS main screen.