DS300f G2 Series User Manual
207
vIewInG nvram eventS
Thisscreendisplaysalistofandinformationabout63mostimportanteventsovermultiplesubsystemstartups.
To display NVRAM events:
1. FromtheMainMenu,highlightEvent Viewer and press Enter.
2. Highlight NVRAM Events and press Enter.
ThelogofNVRAMEventsappears.Eventsareaddedtothetopofthelist.Eachitemincludes:
• Sequence number–Beginswith0atsystemstartup.
• Device–DiskArray,LogicalDrive,PhysicalDrivebyitsIDnumber.
• Severity–SeetheTableonthepreviouspage.
• Timestamp–Dateandtimetheeventhappened.
• Description–Adescriptionoftheeventinplainlanguage.
3. Presstheupanddownarrowkeystoscrollthroughthelog.
checkInG a rePorteD comPonent
Inthisexample,letuscheckdiskarraystatus.
1. OpentheCLU.
2. Highlight Disk Array Management and press Enter.
3. Observethestatusofyourdiskarrays.
DaId Alias OpStatus CfgCapacity FreeCapacity MaxContiguousCap
-------------------------------------------------------------------------------------------
0 DA0 OK 75.44GB 66.06GB66.06GB
1 DA1 Degraded189.06GB 179.68GB179.68GB
2 DA2 OK 73.57GB 64.20GB64.20GB
Atthispoint,youcanhighlighttheDegradedarrayandpressEntertoseemoreinformation.Seebelow.
DiskArrayID:1 PhysicalCapacity:189.06GB
OperationalStatus:Degraded MaxContiguousCapacity:11.18GB
FreeCapacity:179.68GB CongurableCapacity:179.68GB
SupportedRAIDLevels: 0 5 10 1E
Disk Array Alias : DA1
MediaPatrol : Enabled
PDM : Enabled
Transport
Rebuild
Predictive Data Migration
Transition
Dedicated Spare Drives in the Array
Physical Drives in the Array
Logical Drives in the Array
[Locate Disk Array]
SaveSettings [CTRL-A]
RestoreSettings [CTRL-R]
Return to Previous Menu
From this screen:
• Highlight Physical Drives in the Array and press Enter to identify the failed disk drive
• Highlight Rebuild and press Enter to rebuild the array after you replace the failed disk drive